Ice on your heat pump in winter: normal frost or a failed defrost?

A thin coat of frost on a cold, damp Orlando morning is exactly what a heat pump is built to handle. A solid block of ice that never clears is not. How to tell them apart, and what to do until a technician arrives.

People are surprised that a Florida heat pump frosts up at all. It is not even freezing out. But in heat mode the outdoor coil runs 10 to 20 degrees colder than the air around it, because it is pulling heat out of that air. On a 40-degree Orlando morning with fog on the windshield, the coil is below freezing and soaking in moisture. Humid Central Florida mornings frost a coil faster than a dry, much colder day further north.

So frost is expected. What matters is whether it clears.

How defrost is supposed to work

Every 30 to 90 minutes of running in frosting conditions, the defrost control briefly reverses the system into cooling mode. The outdoor fan stops, hot refrigerant runs through the outdoor coil, and the frost melts in two to ten minutes. You may hear a loud whoosh as the valve shifts. You may see a cloud of steam rise off the unit, which has convinced more than one neighbor that the thing is on fire. Water runs out of the base. Then the fan restarts and heating resumes.

Inside, the air may go cool for a few minutes while it happens. That is covered in heat pump blowing cold air in heat mode.

Normal or not

What you seeNormal?What it usually means
Thin, even white frost that clears every hour or soYesDefrost is working
Steam cloud, a whoosh, water draining from the baseYesA defrost cycle just finished
Ice getting thicker over an hour or more and never clearingNoDefrost board, sensor or reversing valve fault
Ice on the top, the fan grille or the fan bladesNoWater is falling on the unit from above
Ice only on the bottom few inches of the coilNoLow refrigerant, or meltwater cannot drain away
Frost when it is 50°F or warmer outsideNoLow refrigerant or an airflow problem

The five causes we find

  1. 1A failed defrost control or sensor. The board never calls for defrost, so the ice builds until the coil is a solid block. A stuck reversing valve looks similar.
  2. 2Low refrigerant. An undercharged system runs the coil colder than designed, so it frosts in milder weather and at the bottom first.
  3. 3An outdoor fan that is not turning. With no air moving across the coil, a bad fan motor or capacitor lets it ice over very fast. Look through the top grille: if the compressor is humming and the fan is still, that is your answer.
  4. 4Water from above. A gutter that overflows onto the unit, a roof valley that sheds onto it, or a sprinkler head aimed at it. Water on a cold coil turns to ice that defrost cannot keep up with. Sprinklers on a freeze night are a classic Central Florida version of this. See what to do on a freeze warning.
  5. 5A unit that cannot drain. Over the years pads settle and mulch builds up around them. When meltwater cannot get away from the base, it refreezes, and the ice climbs the coil from the bottom.

What to do right now

  1. 1Switch the thermostat to Em Heat. That shuts the outdoor unit off and heats the house on the strips. This is the job emergency heat is for.
  2. 2Do not chip, scrape or hit the ice. The fins and tubes are thin. One puncture turns a defrost repair into a refrigerant leak repair.
  3. 3Melt it with a garden hose once the outdoor unit is off. Ordinary tap water is fine. Never use boiling water.
  4. 4Fix the water source if it is coming from above, before you put the unit back in service.
  5. 5Watch it. If it ices up again within a few hours of running normally, it is a fault, not the weather.

What the repair involves

A defrost sensor or board is usually a modest repair, done in one visit. A failed outdoor fan motor or capacitor is the same: we carry the common sizes on the truck. A reversing valve is a refrigerant-circuit job and costs considerably more. On a system past twelve years old, we will talk about whether it is worth doing before we quote it.

The heating diagnostic is $89 and credited to the repair. If the ice is back the morning after a cold night, call before the unit spends another night trying to run through it. More on what we check is on our heating repair page.

Written by

The Eco Air Orlando team — licensed Florida HVAC contractors, #CAC1814992. Everything here comes from work we actually do in Central Florida homes.

Keep reading

More guides

Heating in Florida5 min read

Aux heat vs emergency heat: what your Florida heat pump is telling you

Aux heat for a few minutes is normal. Aux heat all evening on a 50-degree night is a fault, and it can triple what you pay for heat. What each light means, when to use Emergency Heat, and what to check first.

Read →
Energy Savings4 min read

The best thermostat setting for a heat pump in a Florida winter

For a heat pump, setting 68°F and leaving it alone beats the night-setback advice written for gas furnaces. Why heat pumps punish big temperature swings, how to run Auto mode through an 80-degree-afternoon, 48-degree-night November, and the one setting that matters most.

Read →
Energy Savings3 min read

What it costs to heat an Orlando home: heat pump vs heat strips vs space heaters

Real numbers at Central Florida electricity rates, per hour and per month, for the three ways most Orlando homes stay warm. Plus the one situation where a space heater really is the cheaper option.

Read →

Don't sweat it. We'll be there.

If our technician doesn't arrive within 90 minutes of a confirmed emergency dispatch in our core service area, we take $100 off your repair. Licensed FL #CAC1814992 — and a real person answers, day or night.

(407) 777-7241
Call now

Request your free quote

Tell us what's going on and we'll call you back. Or dial (407) 777-7241 — we answer 24/7.

No obligation, no spam. We use your details only to contact you about this request. Prefer to talk? (407) 777-7241